| Two Advantages
but a whole range of benefits . .
. | |
Simple to
install
Fitting your Pro Clear
Advantage unit could not be easier. The unit is
connected into the water circulation system as shown
below and connected to a mains electricity supply in the
same way as fitting a plug.
The unit is designed to be
positioned either on its base on a flat surface, or
attached horizontally to a vertical surface using the
brackets provided, and is supplied with dual
inlet/outlet fittings allowing the unit to be fitted in
the most convenient position
available
Mounting on a
horizontal surface
| If the unit
is to be mounted on a flat surface the supplied
blanking caps should be screwed into the two lower
inlets/outlets as shown in the diagram
below. |
 |
The two universal hosetails
should then be screwed into the other inlet/outlet at
either end of the unit. Hosetails should be tightened
using hand pressure only. The blanking caps should be
inserted and also only tightened by hand . Ensure that
the "O" rings are in position before assembling. Do not
use jointing compound or PTFE tape. Please note that
there is no correct flow direction through the unit.
Either end of the unit may be used as the inlet or
outlet. However, the flow must be from one end of
the unit to the other to ensure correct operation, and
the two blanking caps should be fitted to the inlet and
outlet not being used.
Mounting on a
vertical wall
The unit may be mounted
horizontally onto a vertical wall using the mounting
brackets included (see diagram below). The 8 screws
provided are suitable for fixing the brackets to a
wooden surface. You should ensure that the unit is the
correct way round with the wall spacers positioned at
the back of the unit so that the unit sits securely. The
water connections may be made in either of the
inlets/outlets on the bottom of the unit, the ends of
the unit, or a combination of both (see below).
Please note that there is no correct flow direction
through the unit. Either end of the unit may be used as
the inlet or outlet. However, the flow must be from
one end of the unit to the other to ensure correct
operation, and the two blanking caps should be fitted to
the inlet and outlet not being used. Hosetails should be
tightened using hand pressure only. The blanking caps
should be inserted and also only tightened by hand.
Ensure that the "O" rings are in position before
assembling. Do not use jointing compound or PTFE
tape.
 |
1. Mark the wall
through the brackets then fix with (8)
1"
screws.
2.Vertical wooden
wall or fence |
|
Connection to
the water supply
a.Using flexible
hose
The Pro Clear Advantage unit
is supplied with two universal hosetails to take 1",
114" and
112" diameter flexible
hose. If you are using one of the two larger sizes, the
smaller sections of the hosetails must be cut off to
ensure sufficient water flow and prevent possible damage
to the pump. We recommend that you use the largest
diameter hose available. The hosetails should be trimmed
away from the unit as shown in the diagram below. Using
a hacksaw, carefully cut off the excess hosetail,
ensuring that the sections are cut off at the second
ridge and that the cut follows the line of the
ridge.
 |
Once the
hosetails have been trimmed, attach them to the
unit as described above. Secure the hosepipe to
the hosetail with a stainless steel hose clip. The
hosetails supplied are made from a translucent
material which will glow when the unit is
operating
correctly. |
b.Using rigid
pipe
The unit may also be rigid
plumbed by the use of an adapter (not supplied). The
inlets and outlets of the unit are
112" BSP thread and an
adapter or union (112" male
thread to female plain) to suit your pipework should be
obtained from your nearest supplier of plumbing
fittings.
System
pressure
The unit has been designed
for use with all types of domestic garden pump (working
pressure not to exceed 10psi). Advice should be sought
from your dealer if the unit is to be subjected to
abnormal conditions.
Connection to the
electricity
supply
Mains
electrical cable is not supplied with the unit.
Therefore the user will need to purchase a
suitable length of 3-core live/neutral/earth cable
(0.75mm2). Remove the lid by unscrewing
the four screws on either side of the Pro Clear
Advantage unit. Feed one end of the cable through
the cable clamp and connect to the junction block
as shown below. The remaining cable should be fed
out of the unit via the cable channel in the main
body. Replace the lid and fasten the
screws. |
 |
The other end of the cable
should be connected to a suitable electricity supply. We
strongly recommend the use of an Earth Leakage Circuit
Breaker (ELCB). To allow easy removal of the unit from
the garden during winter months, a waterproof plug and
socket should be used between the unit and any permanent
cable installation.
The electrical cable should
be adequately protected to prevent any damage. If in
doubt consult a qualified
electrician.
Internal fuse
replacement
Always isolate the unit from
the mains supply before undertaking any maintenance. All
units use a 3-amp fuse. Never use a larger rated
fuse.
Easy to
use
Pro Clear Advantage units
require virtually no maintenance and use unique
translucent hose connectors which glow to show that the
UV lamp is working.
Routine
Maintenance
The UV lamp inside the Pro
Clear Advantage unit has a usable life of approximately
7000 hours. As green water is only usually a problem
during spring and summer, the lamp only needs to be
replaced once a year in the spring.
It is essential that the unit
is protected from frost during the winter months, or
disconnected from water and electricity supplies and
stored indoors. During the sp ring and summer season,
the quartz sleeve, which separates the UV lamp from the
water passing through the unit, will need to be cleaned
two or three times . This is essential, as dirt building
up on the quartz sleeve will inhibit the penetration of
the ultraviolet light into the water and effect the
efficient working of the unit.
Lamp
replacement and quartz cleaning
Always isolate the unit from
the electricity and water supplies before carrying out
any maintenance on the unit.
Peel back the rubber end caps
from either end of the unit and carefully pull off the
white plastic electrical end caps. Carefully slide the
lamp out of the unit. Next, unscrew the two compression
fittings located at either end of the main body and
slide off the two "O" rings from either end of the
quartz sleeve (see diagram).
 |
1. Rubber
end cap covering white electrical end
cap 2. Compression
fitting 3. "O"
ring 4. UV
lamp 5. Quartz
sleeve |
Carefully slide out the
quartz sleeve. Clean the sleeve and polish with a soft
cloth or paper towel. If you live in a hard water area
there may be some limescale on the quartz sleeve. This
can be easily removed by soaking the sleeve in a
proprietary kettle descaling solution. Failure to remove
the limescale will limit the effectiveness of the UV
lamp.
Re-assembly
process
Slide the quartz sleeve into
the unit. Ensure that you locate the tow "O" rings
carefully on the ends of the quartz sleeve. Failure to
do so will result in leaks when the water is turned on.
If you are carrying out the annual lamp change, use new
"O" rings. Firmly hand tighten the compression fittings.
Replace the lamp or fit a new one. Relocate the white
electrical end caps onto the pins of the lamp and slide
the rubber endcaps over the compression fittings.
Reconnect and turn on the water supply, carefully
checking for any leaks before switching on the
electricity supply.
Environmentally
safe
Using ultraviolet light, Pro
Clear Advantage Ultraviolet Pond Clarifiers destroy the
green single celled water borne algae which make garden
ponds murky and unattractive As no chemicals are used,
there is no danger of pollution or over treatment of the
water and sensitive plant and pond life is not
affected.
At the heart of each Pro
Clear Advantage unit is an ultraviolet lamp sealed
inside a quartz sleeve. As water is pumped through the
unit, ultraviolet light from the lamp destroys the
algae, leaving the water clear.
Two
sizes available
Pro Clear UV30 which is
suitable for ponds of up to 6000 imp. gallons (27000
litres) with a maximum flow rate of 3000 imp. gallons
(13,500 litres) per hour.
Pro Clear UV55 which is
suitable for ponds of up to 10,000 imp. gallons (45,000
litres) with a maximum flow rate of 4,000 imp. gallons
(18,000 litres) per hour.
For smaller ponds we
recommend our Pond Clear range of UV Pond
Clarifiers.
Which size will
your pond require?
The main factors which govern
the model you will need are pond size, stocking level
and the amount of sunlight the pond is subject to. Use
the table below to select the correct model for your
pond. If in doubt, ask your dealer or phone the
technical advice number overleaf.

Free technical
advice
As a
service to our customers, Tropical Marine Centre offers
free technical advice on Pro Clear Advantage
products.
Simply call 01923 284151
between 9am and 5pm Monday to Thursday and between 9am
and 2pm on Fridays.
The reliable aquatics
supplier
Tropical Marine Centre has
been established for over 27 years and pioneered the
development of ultraviolet water clarifying
equipment.
Pro Clear Advantage products
are designed for reliability and a long working life.
Spare parts and replacement lamps are always readily
available.
Multi-lingual
information
Information and instruction
leaflets on the Pro Clear Advantage units are available
in English, French, German, Dutch and Italian.
A German version of the Pro Clear
Advantage unit and packaging is also
available.
Important
Safety Information - Please read carefully
- Never look directly at an
illuminated UV lamp.
- Do not run the unit dry.
- Always isolate the unit
from the mains electricity and turn off the water
supply before carrying out any maintenance.
- We strongly recommend the
use of an Earth Leakage Circuit Breaker (ELCB).
- This unit must be earthed.
- Never use a fuse larger
than 3 amps.
- Rating: 220-240v.
50Hz. UV30-30 watt/UV55 - 55 watt. Class 1 IP44.
- The unit must not be
submerged in water
- Do not cover the unit.
- If the quartz sleeve is
broken or cracked it must be replaced immediately to
prevent leaks.
- The unit must be either
fully frost protected or taken inside during the
winter months.
Product
Information
- The units are manufactured
and conform to BS EN 60598
- The units conform to the
low voltage directive (safety) CEE 73 23.
- The units conform to the
EMC directive CEE 89 336
- The units are CE
approved
Accessories
and Spare Parts
All parts in our Pro Clear
Advantage units are individually replaceable and we
supply a full range of spares including replacement UV
lamps, quartz sleeves, hosetails and "O"
Rings. |